TS6035A-043B 2 pins PCB foot tact switch, 6X3.5mm height is 4.3mm, SMD SMT tactile push button switch
Series:TS6035A
2. DETAIL SPECIFICATIONS:
Type: TS6035A-043B
Operation method: Tact Action
Configuration: Instrument with feeling feedback
Terminal form: PCB type SMT type(□BRAID □NO BRAID)
Mounting: Soldering
Protection: Comply with ■IP40 □IP65 □IP67 □IP68
![]()
- Applications
- Technical parameters
- Remarks
-
1.Audio Products:MP3,MP4,DVD. Audio;
2.Digital Products: digital camera, digital video and so on;
3.Remote Control: the remote control of automobile domestic security products;
4.Communication Products: mobile phone, vehicle-mounted phone, telephone set, building equipment, PDA and so on;
5.Homehole appliances: TV set, microwave oven, electric rice cooker, electric fans ,refrigerator,washer;air-conditioning and so on;
6.Security Products: visual interphone, monitor and so on;
7.Toys: electric toys and so on;
8.Computer Products: PC camera and so on;
9.Exercises Machines: treadmills, massage armchair and so on;
10.Medical Device: sphygmomanometer, thermometer, hospital call system and so on;
11.Others: laser pen ,Pointer,Wireless mouse remote control pen,Laser projection pen,page turner,electronic pen;MousePen;overhead projector and so on;
12.Operating switches in all types of electronic equipment such as audio devices, office devices, communication devices, measuring instruments, TVs, video recorders,automotive sets, etc.
13.Household appliances, electric force, telecommunications, machine tool, vessel, textile, printing, Mining machine, Music Instrument, etc.
2.1 General
2.1.1 Application This specification is applied to TACT Switch used for electronic equipment.
2.1.2 Operating temperature range -20℃ ~ +70℃
2.1.3 Storage temperature -30℃ ~ +80℃
2.1.4 Test conditions
Ambient temperature 5~35℃
Relative humidity 45~85%
Air pressure 86~106kPa (860~1060 mbar)
If any doubt arise from the judgment, tests shall be conducted at the following conditions.
Ambient temperature: 20±2℃
Relative humidity60~70%
Air pressure 86~106kPa (860~1060 mbar)
2.2 Appearance construction and dimensions
2.2.1 Appearance Switch shall have good finishing, and no rust crack or plating failures.
2.2.2 Construction and dimensions Refer to individual product drawing.2.3. ELECTRICAL SPECIFICATION
NO.
Items
Test conditions
Criteria
2.3.1
Contact resistance
Shall be measured at 10mA 5VDC by
voltage drop method after some
operations without load.
Applied position: Between terminal
and terminal
50mΩ MAX
2.3.2
Insulation resistance
Test voltage:100VDC, measured after
1 min ±5s
Applied position: 1)Between terminal
and terminal
2)Between terminal and ground
100MΩ MIN
2.3.3
Voltage proof
Following test voltages shall be
applied for 1 min.
(Cut-off current:0.5mA)
1)Between terminal and terminal :
250VAC (50~60Hz)
No dielectric breakdown
shall occur
2.3.4
Contact bounce
Lightly striking the center of the stem
at a rate encountered in normal use
(3 to 4 times per second), and bounce shall be tested at “ON”
and “OFF”

ON-3msec.max
OFF-8msec.max
2.4. ENVIRONMENT RESISTANCE
NO.
Items
Test conditions
Criteria
2.4.1
Cold
After testing at -30±2℃ for 96 h,
the switch shall be allowed to stand under
normal room temperature and humidity
condition for 1h, and then
measurement shall be made within 1 h.
waterdrops shall be removed.
Contact resistance:
200mΩ MAX
Insulation resistance:
50MΩ MIN
Voltage proof:
No dielectric
breakdown
shall occur.
Operating
characteristic
variety
Within ±10% of
specified value .
2.4.2
Dry heat
After testing at 80±2℃ for 96 h, the switch
shall be allowed to stand under
normal room temperature and humidity
condition for 1h, and then
measurement shall be made within 1 h.
2.4.3
Damp heat
After testing at 60±2℃ and 90-95%RH
for 96 h, the switch shall be allowed
to stand under normal room temperature
and humidity condition for 1h,
and then measurement shall be made
within 1 h. water drops shall be
removed.
2.4.4
Change of
temperature
After 20 cycles of following conditions
the switch shall be allowed to stand
under normal room temperature and
humidity condition for 1h, and then
measurement shall be made within
1 h. water drops shall be removed.
2.4.5
Sulfuration resistance
When endured a temperature of 40
+ 2 DEG relative humidity of 90-95%
RH gas concentration, H2S: 3ppm +
1ppm, 8
hours after the test, the
switch in normal temperature and
humidity conditions
to recover for
1 hours, then measuring in 1 hours.
To remove the gel.
2.4.6
Salt mist
he switch shall be checked after
following test:
1) Temperature: 35℃±2℃
2) Salt solution : 5±1%(solids
by mass)
1) Time: 8±1 hour
After test, salt deposit shall be
removed by running water.
No abnormalities
shall be recognized
in appearance and
construction.
2.5. WELDING PERFORMANCE
2.5.1
Solder ability
Switch test under such conditions
and inspect after.
1)Variable temperature range :
245±5℃;
2)Dip time:2±0.5s;
The area of dip tin
should capture the
90% impregnated area
2.5.2
Resistance to
soldering heat
The switch will be inspect under
such conditions below
Temperature and impregnated time
Trial measure
Temperature(℃)
Time(s)
Slot welding
method
260±5
5±1
Soldering method
350±5
3±0.5
All of the appearance,
motor functions,
electrical properties
are no abnormal.
2.6. DURABILITY
2.6.1
Operation life
Measurement shall be made following
the test set forth below: DC 12V, 50
mA resistance load;
Rate of operation:120 times/min.;
Operating Force:1.5OF; Average
fault-free life: 100,000 cycles
Contact
resistance:
≤200mΩ
Contact
bounce:
≤10ms
Operating
Force:
initial value
±30%
2.6.2
Vibration
Measurement shall be made following
the test set forth below:
1) Vibration frequency range: 10Hz to
55Hz to 10Hz;
2) Amplitude: 1.5mm;
3) Direction of vibration: three mutually
perpendicular direction including the
direction of stem travel
4) Duration: Each 2hours.
2.6.3
Operation Force
The switch is placed perpendicular to the
direction of the operation, gradually force
in key top center
of switch, measure maximum intensity
when it conducted required.
180±50gf
2.6.4
Over Travel
Switch at the vertical operating orientation
placement, with a force equal to 2 times
according to the
static load applied on the switch button
the top center, measure the top moving
distance
0.25±0.10mm
2.6.5
Resilience
The switch is placed perpendicular to the
direction of the operation, the switch key
top center fell to
a full stroke, the converted measurement
from the top of the intensity of free position.
50gf.min.
2.6.6
Stop strength
The switch is placed perpendicular to the
direction of the operation, the static load
applied 30N from
the operation direction keys to continue
1min.
no
mechanism
and
electricity
damage
2.6.7
handle pull
out strength
The switch is placed perpendicular to the
direction of the operation, applying tension
on the keys
from the opposite direction of operation,
measure the maximum tension when the
key is pulled out.
20N.min.
3. DRAWING & DIMENSION:

PARTS LIST:
NO
NAME
MATERIAL
1
1
Terminal
H65 silver plated brass
2
1
Case
PA66-G30 Black
3
1
Contact
F.Ag/C5210 Contact side silver plating
4
1
Cover
SPCCC-SD CuSn plating
5
1
Plunger
PA66-G30 Black
Returned plastic should not exceed 20%.

Skype