RE1202EJ1-H01 encoder with three pins

Series:RE1202EJ1 series

Description:

Type:                             RE1202EJ1-H01
Construction category:    D
Operation method:          Push button switch
Configuration:                 Double-Pole Double-Through (DPDT)
Terminal form:                Solder Terminal
Protection:                     IP40

Contact Now

  • Applications
  • Technical parameters
  • Remarks

Widely used in home appliance, electronic equipment, automatic machine, communication equipment, car electron, apparatus and instrument, electric motion tool etc.
Rice cooker
Slow cooker
Electric Heating Faucet
Shredder
Computer mouse
Electromagnetic lock
Baby chair
CNC machine tools
Power generator
Test equipment
Elevator
Power tools
Air conditioner
Water heater control panel
Bathroom products
Vacuum cleaner
Kitchen products
Gas valve
Range hood machine
Microwave oven
Pass-through machine


1.  General Characteristic

1.1 Application: This specification is applied to rotary encoder used for general application.

1.2 Operating Temperature Range: -25℃to +85℃

1.3 Operating Relative Humidity:    ≤85%

1.4  Test Conditions: Unless otherwise specified, the atmospheric conditions for making measurements  and tests are as follows:

Environment Temperature 5~35℃

Relative Humidity:  45~85%

Atmospheric Pressure  86~106Kpa (860~1060mbar)

86~106Kpa (860~1060mbar)

2. Rating 

Rotational10mA   5VDC (Resistance load) Push-on0.5A 16VDC (Resistance load)

4.   Electrical Characteristics     

No.

Item

Criteria

Test Method

4.1

Contact

Resistance

200mΩ Max.

Any equipment with error not more than 5% can be used. Resistance after test is the average of 5 successive measurements.   To turn after operated 5 to 10 circles

4.2

Insulation

Resistance

100MΩ Min

250VDC voltage is  applied  between each pair  of  terminals and between the terminal and the metal frame for 60±5S.

4.3

Dielectric

Voltage

No    dielectric    breakdown    shall occur.

300VAC  (50~60Hz,  cut  –off  current  2mA)  is  applied  between non-connected  terminals and between terminals and the metal frame for 60 ±5s.

4.4

Output Signal Format

 

Oscillogram and click points

2 Phase-different signals signal A, signal BDerails shown in The broken line shows detent position.

Shaft rotational direction

Signal

OutputPlease  refer to the drawing about the rotating direction

C.W.

ATerminal AC


BTerminal BC

C.C.W.

ATerminal AC
BTerminal BC

Phase-diffe rence

T1.T2.T3.T4:≥6ms

4.5

Bouncing

Between 3.5V and 1.5V Measurement circuit Diagram 1

Measure condition:360°/s

for rotational speed t1. t3: 3ms Max.

t2: 2ms Max.


5.   Mechanical Characteristics

No.

Item

Criteria

Test Method

5.1

Detent

Points

30   detent   points   each   detent angle:12°±3°

Rotation 360°

5.2

Output

Resolution

15 pulse/360°

Rotation 360°

5.3

Rotational Torque

80200gf.cm

Apply a tension meter on the midpoint of the actuator (or tip of the shaft)  to  supply  a  pressure  vertically  from  its  free  position  to operating position.

5.4

Shaft play in axial direction

0.3mm Max.

Push and pull static load of 3N shall be applied  to the shaft in axis directions.

5.5

Rotation play at the click position

3°Max.

In the top of the shaft press on 30gf.cm rotation torque mensuring rotating shaft angle.

5.6

Terminal

Strength

After test,

Electrically and mechanically performances shall be satisfied.

Applying 3N to the terminal end of the force  for 10 ± 1s in any direction.

5.7

Vibration Proof

After test,

Electrically and mechanically performances shall be satisfied.

Install   the   encoder   to   the   test   equipment   with   conventional installation methods,do test under the following spec. conditions:

(1) Vibration frequency range = 10~55 Hz

(2)  Total amplitude  =1.5mm

(3) Sweep ratio: 10~55~10Hz Approx. 1 min

(4) Method of changing the sweep vibration frequency: linear

(5)  Direction of vibration: Three perpendicular  directions including actuating direction.

(6) Duration: 2 hours (6 hours in total)

5.8

Mechanical

Shock

After test,

Contact resistance: 5ΩMax. Insulation resistance:10MΩ Min. The Electrical performance requirements  specified in item

4.3-4.5shall be satisfied.

Shall be free from mechanical abnormalities.

Encoder shall be tested according to the following request: (1) Mounting Method: Normal

(2) Acceleration: 490m/s² (50G)

(3) Duration:  11ms

(4) Test Direction: 6 directions

(5)Number of shocks: 3 times per direction (18 times in total

6. Durability characteristic

No.

Item

Criteria

Test Method

6.1

Mechanical

Life

After test,

1 Contact resistance: 5ΩMax.

2 Insulation resistance:

10MΩ Min.

3  Phase-difference

T1.T2.T3 .T4: ≥4ms

4  Bouncing

t1. t3: 3ms Max. t2:2ms Max.

5  Rotational torque

The variation of the detent torque sall be within 30%

6 Dielectric strength

50V AC for 1minute Min. No dielectric breakdown.

100,000 circles of operation shall be performed continuously at a rate of 1 cycles per Second without load360° for a circle).

7. Soldering Characteristics

No.

Item

Criteria

Test Method

7.1

Solder Ability

More than 95 of immersed  part shall be covered with solder.

Encoder shall be tested according to the following request: (1)Solder:    Sn-3.0 Ag-0.5 Cu tin/lead-free.

(2)Flux: Rosin Flux having a nominal composition of 25% solids by

mass of water white rosin in methyl alcohol solution.

(3)Solder temperature: 255±5℃.

(4)Immersion time: 3±1 seconds.

7.2

Resistance To Soldering Heat

After test,

Electrically and mechanically performances shall be satisfied.

Encoder shall be tested according to the following request: (1) Soldering Temperature & Immersing Time(tin/lead-free):

Wave soldering: 260°C Max   5s Max

Manual soldering:   350°C Max   2-3s

(2) Solder:    Sn-3.0 Ag-0.5 Cu tin/lead-free.

(3) Flux: Rosin Flux having a nominal composition of 25% solids by mass of water white rosin in methyl alcohol solution.

(4) rate of immersion and emergence:

25(±6)mm(1.00±0.25in.), per second

(5) Immersion Depth:

The required depth of immersion is to within 1~1.5mm of the device body.

(6)Wave soldering times :   2 times.

(7)The interval between two weldings should be more than 2 hours

8. Weather Proof Characteristics

No.

Item

Criteria

Test Method

8.1

Low Temperature Test

After test,

Contact resistance: under 2 times the initial value.

Insulation resistance:10MΩ Min.

10MΩ Min.

Rotation torqueInitial torque

±30%

Push forceInitial operation force

±30%

The performance requirements specified in item 4.1-5.3 shall be satisfied.

The encoder shall be stored at a temperature of –40±2°C for 192 hours  in  a thermostatic  chamber,.  And  then  the  encoder  shall  be subjected  to standard  atmospheric  condition  for 1 hour after which measurements  shall be made

8.2

High Temperature Test

The encoder shall be stored at a temperature of 85 ± 2°C for 192 hours  in a thermostatic  chamber,.  And then  the encoder  shall  be subjected  to standard  atmospheric  condition  for 1 hour after which measurements  shall be made

8.3

Steady State Damp Heat Test

The encoder shall be stored at a temperature of 60±2°C with relative humidity  of 90% to 95% for 192 hours  in a thermostatic  chamber,. And then the encoder shall be subjected to standard atmospheric condition for 1 hour after which measurements shall be made.

8.4

Temperature Cycling

After 5 cycles of following conditions, the encoder shall be allowed to stand under normal temperature and humidity conditions for 1 hour, and measurement shall be made within 1 hour after that.

8.5

Salt Mist

After test,

Electrically and mechanically performances shall be satisfied.

The encoder shall be checked after the following test: (1)  Temperature: 35± 2°C

(2)  Salt Solution: 5±1% (Solids by mass).

(3)  After immersing, salt deposit shall be removed by running water. (4)  Duration: 4hours

9.Drawing



  

10.storage conditions

10.1

storage conditions

After test

Contact resistance: under 2 times the initial value.

Insulation resistance:    10MΩ Min.

 

 

The performance requirements specified in item 4.1-5.3 shall be satisfied.

 

No abnormalities shall be observed in appearance and operation.

The products shall be stored in the original packaging and kept at room temperature  and humidity,out  of direct sunlight,and  away from any and all corrosives gas.The products shall be completely used as soon as possible,but no later than 6 months from the date of delivery. Temperature:5°C~35°C

Humidity:  45%~85% Keeping period: one year.