MS1-01ZSW0-C015 Snap Action Switch SPDT #187Terminals

Series:MS1 series

Description:

Type:MS1-01ZSW0-C015
Construction category:D type
Operation method:Snap Action
Configuration:Single-Pole Double -Throw (SPDT)
Terminal form:#250 Quick-connect Terminal
Mounting:via side mounting holes
Protection:IP40

Contact Now

  • Applications
  • Technical parameters
  • Remarks

Widely used in home appliance, electronic equipment, automatic machine,
communication equipment, car electron, apparatus and instrument, electric motion tool etc.

Rice cooker
Slow cooker
Electric Heating Faucet
Shredder

Baby chair
CNC machine tools
Power generator
Test equipment

Air conditioner
Water heater control panel
Bathroom products
Vacuum cleaner


3.DETAIL SPECIFICATIONS
Type:MS1-01ZSW0-C015
Construction category:D type
Operation method:Snap Action
Configuration:Single-Pole Double -Throw (SPDT)
Terminal form:#187 Quick-connect Terminal
Mounting:via side mounting holes
Protection:IP40
3.1OPERATING CHARACTERISTICS

Characteristics

Units

Standards

Note

Actuating Force

N

0.15 Max

Original 0.15 Max

Pre Travel 

mm

1.2mm MAX

Original 1.2mm MAX

Operating Position

mm

14.7 ± 0.5

Original 14.7 ± 0.5

Note:
Actuating Force:
The force required to move the actuator from the free to the operation position
Release Force
The force allowed the mechanism to reset actuator after operation
Free Position
The position of the actuator when no external force is applied
Operating Position
The position of the actuator when contact change-over take place
Movement Differential
The distance between operation and release position           

3.2 General
3.2.1 Application This specification is applied to MS1 Micro Switch used for electronic equipment.
3.2.2 Operating Temperature range  -40℃ +125℃
3.2.3 Test condition Unless otherwise specified. The atmospheric conditions for making measurements                

And tests are as follows:
Ambient temperature: 15~35℃
Relative humidity: 45~85%
Air pressure: 86~106kPa (860~1060 mbar)
Should any doubt arise in judgment. It shall be conducted at the following conditions.
Ambient Temperature: 20±2℃
Relative humidity: 60~70%
Air pressure: 86~106kPa (860~1060 mbar)
3.3 Appearance Construction and Dimension
3.3.1 Appearance Switch shall have good finishing, and no rust crack or plating failures.
3.3.2construction and dimensions Refer to individual product drawing.
3.4. Electrical Specifications

NO.

Item

Test Condition

Criteria

3.4.1

Contact Resistance

Shall be measured at 1A,5V DC by voltage

 drop method after some operations 

without load.

Applied position: Between terminal “C” and terminal “NO”.

100mΩ MAX

3.4.2

Insulation Resistance

Test voltage:500VDC, measured after 1 min ±5s

Applied Position: applied position: 
1)Between terminal “C” and terminal “NO”

2)Between terminal and ground

100MΩ MIN

3.4.3

Voltage proof

Following test voltages shall be applied for 1 min.

1)Between terminal “C” and terminal

 “NO”:1000VAC (50~60Hz)

2)Between terminal and ground: 1500V AC(50~60Hz)

No dielectric 

breakdown 

shall occur

3.5. Durability

NO.

Item

Test Condition

Criteria

3.5.1

Cold

After testing at -40±2℃ for 96 h, the switch shall be allowed to stand under normal room temperature and humidity condition for 1h, and then measurement shall be made within 1 h. water drops shall be removed.

 

Contact resistance(item 4.1):

100mΩ MAX

Insulation resistance (item 4.2):

50MΩ MIN

Voltage proof: (item 4.3)

No dielectric breakdown shall occur.

Within 10% of specified
value .

No abnormalities shall be recognized in appearance and construction

 

3.5.2

Dry heat

After testing at 125±2℃ for 96 h, the switch shall be allowed to stand under normal room temperature and humidity condition for 1h, and then measurement shall be made within 1 h.

3.5.3

Damp Heat

After testing at 40±2℃ and 90-95%RH for 96 h, the switch shall be allowed to stand under normal room temperature and humidity condition for 1h, and then measurement shall be made within 1 h. water drops shall be removed.

3.5.4

Change of Temperature

low temperature-40±2℃,high temperature125±2℃。High and low temperature and constant temperature each 3hours .After four test cycle temperature changes, switch under the normal temperature and humidity ,then complete the measurement in 1hour,need removed the condensation.

3.6 Durability

NO.

Item

Test Condition

Criteria

 

3.6.1

 

Endurance

(According to

 UL61058)

 

 

0.1A  125VAC

Operation Cycles:50,000 cycles;

Operation Frequency:15~20 cycles/m

Voltage proof:Test voltage shall be applied for 1 min(50~60Hz, Cut-off current:0.5mA)

 

 

Insulation 

resistance

(item 4.2):

50MΩ MIN

Voltage 

proof:

Terminal and 

terminal:

1000VAC

No dielectric 

breakdown

 shall 

occur.

 

Operating 

characteristic

(item 5.1):

Within 20% 

of specified
value .

 

6000 cycles

temperature 

rise: 30℃ 

MAX

10000cycles 

temperature 

rise: 55℃ 

MAX

No 

abnormalities 

shall be 

recognized in 

appearance 

and 

construction.

 

3.6.2

 

Endurance

(According to

 EN61058-1

/IEC61058-1)

 

0.1(0.05)A  250V AC;

Operating Cycles:50,000 cycles

Operation Frequency:15~20 cycles/m

Voltage proof:Test voltage shall be applied for 1 min(50~60Hz, Cut-off current:0.5mA)

 

 

 

 

Insulation resistance(item 4.2):

50MΩ MIN

Voltage proof:

Terminal and terminal:750VAC

Terminal and ground:1125VAC

No dielectric breakdown shall occur.

Operating characteristic (item 3.1):

Within ±20% of specified value .

Temperature rise:55℃ MAX

No abnormalities shall be recognized in appearance and construction

 

 

 

4. DRAWING & DIMENSION

5. CIRCUIT DIAGRAM

6.  PACKING:

6.1

 Packing material:

Plastic box / 
Double-layers paper carton

6.2

 Packing number:

100 pieces per box 
4 inner cartons per shipping carton
Each shipping carton 10000 pieces

6.3

Weight:

Gross Weight:  8.5kg

 Net Weight:  7.0kg

6.4

 Size:

31.0 x 25.0 x 34.5 CM / 0.045CBM

SAFETY APPROVAL & RATING:

Approved Rating

Mark

Reference No.

0.1A125VAC T125  0.1GPA 125/250VAC  5E4 40T125  50-60Hz

UL&CUL

E176213

 

VDE

 

0.1(0.05)A250VAC 5E4 10T125

CQC

CQC05002012548

 

NEMKO

 

0.1(0.05)A250VAC 5E4 10T125

SEMKO

1018901

 

FIMKO

 

0.1(0.05)A 125/250VAC  5E4 40T125  50-60Hz

DEMKO

D-01730-A2-M1

0.1(0.05)A250VAC 5E4 10T125

CE

SH10030591-V1

 

TUV

 

0.1(0.05)A250VAC 5E4 10T125  

0.1(0.05)A 125/250VAC  5E4 40T125  50-60Hz

ENEC

SE/0488-03

ENEC-00376-A2-M1

0.1(0.05)A 250VAC     1E4 10T125

EK

SU02030-7001A

1(0.05)A 125/250VAC   5E4 40T125  50-60Hz

CB

DK-28372-A2-M1-UL

return