MS1-01ZSW0-C015 Snap Action Switch SPDT #187Terminals
Series:MS1 series
Type:MS1-01ZSW0-C015
Construction category:D type
Operation method:Snap Action
Configuration:Single-Pole Double -Throw (SPDT)
Terminal form:#250 Quick-connect Terminal
Mounting:via side mounting holes
Protection:IP40
- Applications
- Technical parameters
- Remarks
-
Widely used in home appliance, electronic equipment, automatic machine,
communication equipment, car electron, apparatus and instrument, electric motion tool etc.
Rice cooker
Slow cooker
Electric Heating Faucet
Shredder
Baby chair
CNC machine tools
Power generator
Test equipment
Air conditioner
Water heater control panel
Bathroom products
Vacuum cleaner
3.DETAIL SPECIFICATIONS
Type:MS1-01ZSW0-C015
Construction category:D type
Operation method:Snap Action
Configuration:Single-Pole Double -Throw (SPDT)
Terminal form:#187 Quick-connect Terminal
Mounting:via side mounting holes
Protection:IP40
3.1OPERATING CHARACTERISTICSCharacteristics
Units
Standards
Note
Actuating Force
N
0.15 Max
Original 0.15 Max
Pre Travel
mm
1.2mm MAX
Original 1.2mm MAX
Operating Position
mm
14.7 ± 0.5
Original 14.7 ± 0.5
Note:
Actuating Force:
The force required to move the actuator from the free to the operation position
Release Force
The force allowed the mechanism to reset actuator after operation
Free Position
The position of the actuator when no external force is applied
Operating Position
The position of the actuator when contact change-over take place
Movement Differential
The distance between operation and release position3.2 General
3.2.1 Application This specification is applied to MS1 Micro Switch used for electronic equipment.
3.2.2 Operating Temperature range -40℃ ~ +125℃
3.2.3 Test condition Unless otherwise specified. The atmospheric conditions for making measurementsAnd tests are as follows:
Ambient temperature: 15~35℃
Relative humidity: 45~85%
Air pressure: 86~106kPa (860~1060 mbar)
Should any doubt arise in judgment. It shall be conducted at the following conditions.
Ambient Temperature: 20±2℃
Relative humidity: 60~70%
Air pressure: 86~106kPa (860~1060 mbar)
3.3 Appearance Construction and Dimension
3.3.1 Appearance Switch shall have good finishing, and no rust crack or plating failures.
3.3.2construction and dimensions Refer to individual product drawing.
3.4. Electrical SpecificationsNO.
Item
Test Condition
Criteria
3.4.1
Contact Resistance
Shall be measured at 1A,5V DC by voltage
drop method after some operations
without load.
Applied position: Between terminal “C” and terminal “NO”.
100mΩ MAX
3.4.2
Insulation Resistance
Test voltage:500VDC, measured after 1 min ±5s
Applied Position: applied position:
1)Between terminal “C” and terminal “NO”2)Between terminal and ground
100MΩ MIN
3.4.3
Voltage proof
Following test voltages shall be applied for 1 min.
1)Between terminal “C” and terminal
“NO”:1000VAC (50~60Hz)
2)Between terminal and ground: 1500V AC(50~60Hz)
No dielectric
breakdown
shall occur
3.5. Durability
NO.
Item
Test Condition
Criteria
3.5.1
Cold
After testing at -40±2℃ for 96 h, the switch shall be allowed to stand under normal room temperature and humidity condition for 1h, and then measurement shall be made within 1 h. water drops shall be removed.
Contact resistance(item 4.1):
100mΩ MAX
Insulation resistance (item 4.2):
50MΩ MIN
Voltage proof: (item 4.3)
No dielectric breakdown shall occur.
Within 10% of specified
value .No abnormalities shall be recognized in appearance and construction
3.5.2
Dry heat
After testing at 125±2℃ for 96 h, the switch shall be allowed to stand under normal room temperature and humidity condition for 1h, and then measurement shall be made within 1 h.
3.5.3
Damp Heat
After testing at 40±2℃ and 90-95%RH for 96 h, the switch shall be allowed to stand under normal room temperature and humidity condition for 1h, and then measurement shall be made within 1 h. water drops shall be removed.
3.5.4
Change of Temperature
low temperature-40±2℃,high temperature125±2℃。High and low temperature and constant temperature each 3hours .After four test cycle temperature changes, switch under the normal temperature and humidity ,then complete the measurement in 1hour,need removed the condensation.
3.6 Durability
NO.
Item
Test Condition
Criteria
3.6.1
Endurance
(According to
UL61058)
0.1A 125VAC
Operation Cycles:50,000 cycles;
Operation Frequency:15~20 cycles/m
Voltage proof:Test voltage shall be applied for 1 min(50~60Hz, Cut-off current:0.5mA)
Insulation
resistance
(item 4.2):
50MΩ MIN;
Voltage
proof:
Terminal and
terminal:
1000VAC
No dielectric
breakdown
shall
occur.
Operating
characteristic
(item 5.1):
Within 20%
of specified
value .6000 cycles
temperature
rise: 30℃
MAX;
10000cycles
temperature
rise: 55℃
MAX;
No
abnormalities
shall be
recognized in
appearance
and
construction.
3.6.2
Endurance
(According to
EN61058-1
/IEC61058-1)
0.1(0.05)A 250V AC;
Operating Cycles:50,000 cycles
Operation Frequency:15~20 cycles/m
Voltage proof:Test voltage shall be applied for 1 min(50~60Hz, Cut-off current:0.5mA)
Insulation resistance(item 4.2):
50MΩ MIN
Voltage proof:
Terminal and terminal:750VAC
Terminal and ground:1125VAC
No dielectric breakdown shall occur.
Operating characteristic (item 3.1):
Within ±20% of specified value .
Temperature rise:55℃ MAX
No abnormalities shall be recognized in appearance and construction4. DRAWING & DIMENSION
5. CIRCUIT DIAGRAM
6. PACKING:
6.1
Packing material:
Plastic box /
Double-layers paper carton6.2
Packing number:
100 pieces per box
4 inner cartons per shipping carton
Each shipping carton 10000 pieces6.3
Weight:
Gross Weight: 8.5kg
Net Weight: 7.0kg
6.4
Size:
31.0 x 25.0 x 34.5 CM / 0.045CBM
SAFETY APPROVAL & RATING:
Approved Rating
Mark
Reference No.
0.1A125VAC T125 0.1GPA 125/250VAC 5E4 40T125 50-60Hz
UL&CUL
E176213
VDE
0.1(0.05)A250VAC 5E4 10T125
CQC
CQC05002012548
NEMKO
0.1(0.05)A250VAC 5E4 10T125
SEMKO
1018901
FIMKO
0.1(0.05)A 125/250VAC 5E4 40T125 50-60Hz
DEMKO
D-01730-A2-M1
0.1(0.05)A250VAC 5E4 10T125
CE
SH10030591-V1
TUV
0.1(0.05)A250VAC 5E4 10T125
0.1(0.05)A 125/250VAC 5E4 40T125 50-60Hz
ENEC
SE/0488-03
ENEC-00376-A2-M1
0.1(0.05)A 250VAC 1E4 10T125
EK
SU02030-7001A
1(0.05)A 125/250VAC 5E4 40T125 50-60Hz
CB
DK-28372-A2-M1-UL