KW10-ZSW0P075-08 Gold Plated PCB Terminal Micro Switch
Series:KW10 series
Type: KW10-ZSW0P075-08
Construction category: D type
Operation method: Snap Action
Configuration: Single-Pole Double-Throw (SPDT)
Terminal form: PCB Terminal
Mounting: via side mounting holes
Protection: Comply with IP40
- Applications
- Technical parameters
- Remarks
-
Widely used in home appliance, electronic equipment, automatic machine,
communication equipment, car electron, apparatus and instrument, electric motion tool etc.
CNC machine tools
Power generator
Test equipment
Elevator
Power tools
Bathroom products
Vacuum cleaner
Kitchen products
Range hood machine
Pass-through machine
3.DETAIL SPECIFICATIONS:
Type:KW10-ZSW0P075-08
Construction category:D type
Operation method:Snap Action
Configuration:Single-Pole Double-Throw (SPDT)
Terminal form:PCB Terminal
Mounting:via side mounting holes
Protection:Comply with IP40
3.1OPERATING CHARACTERISTICSCharacteristics
Units
Standards
Note
Actuating Force
N
0.75N Max
Original 0.75max.
Free Position
mm
6Max
Original 6max.
Operating Position
mm
5.5± 0.3
Original 5.5± 0.3
Note:
Actuating Force:
The force required to move the actuator from the free to the operation position
Release Force
The force allowed the mechanism to reset actuator after operation
Free Position
The position of the actuator when no external force is applied
Operating Position
The position of the actuator when contact change-over take place
Movement Differential
The distance between operation and release position3.2 General
3.2.1 Application This specification is applied to KW10 Micro Switch used for electronic equipment.
3.2.2 Operating Temperature range -40℃ ~ +85℃
3.2.3 Test condition Unless otherwise specified. The atmospheric conditions for making measurements And tests are as follows:
Ambient temperature: 15~35℃
Relative humidity: 45~85%
Air pressure: 86~106kPa (860~1060 mbar)
Should any doubt arise in judgment. It shall be conducted at the following conditions.
Ambient Temperature: 20±2℃
Relative humidity: 60~70%
Air pressure: 86~106kPa (860~1060 mbar)
3.3 Appearance Construction and Dimension
3.3.1 Appearance Switch shall have good finishing, and no rust crack or plating failures.
3.3.2construction and dimensions Refer to individual product drawing.
3.4. Electrical SpecificationsNO.
Item
Test Condition
Criteria
3.4.1
Contact
Resistance
Shall be measured at 1A,5V DC by voltage drop
method after some operations
without load.
Applied position: Between terminal “C”
and terminal “NO”.
50mΩ MAX
3.4.2
Insulation
Resistance
Test voltage:500VDC, measured after 1 min ±5s
Applied Position: applied position:
1)Between terminal “C” and terminal “NO”2)Between terminal and ground
100MΩ MIN
3.4.3
Voltage
proof
Following test voltages shall be applied for 1 min.
1)Between terminal “C” and terminal
“NO”:600VAC (50~60Hz)
2)Between terminal and ground: 1000V
AC(50~60Hz)
No dielectric
breakdown
shall occur
3.5. Durability
NO.
Item
Test Condition
Criteria
3.5.1
Cold
After testing at -40±2℃ for
96 h, the switch shall be allowed to
stand under normal room
temperature and humidity condition for
1h, and then measurement shall
be made within 1 h. water drops
shall be removed.
Contact resistance(item 4.1):
100mΩ MAX
Insulation resistance (item 4.2):
50MΩ MIN
Voltage proof: (item 4.3)
No dielectric breakdown shall occur.
Within 10% of specified
value .No abnormalities shall be recognized
in appearance and construction
3.5.2
Dry heat
After testing at 85±2℃ for 96 h,
the switch shall be allowed to
stand under normal room
temperature and humidity condition
for 1h, and then measurement
shall be made within 1 h.
3.5.3
Damp Heat
After testing at 40±2℃ and
90-95%RH for 96 h, the switch shall
be allowed to stand under
normal room temperature and
humidity condition for 1h, and
then measurement shall be made
within 1 h. water drops shall
be removed.
3.5.4
Change of
Temperature
After 5 cycles of following
conditions the switch shall be allowed
to stand under normal room
temperature and humidity condition
for 1h, and then measurement
shall be made within 1 h. water
drops shall be removed.
3.5.5
Salt Mist
Switch shall be checked
after following lest.
1) Temperature: 35±2℃
2) Salt solution: 5±1%
(solids by mass)
3) Duration: 24±1h
After test, salt deposit shall
be removed in running water
No remarkable corrosion
shall be recognized in metal part
3.6. Welding Performance
3.6.1
Solder
ability
Switch test under such conditions and inspect after.
1)Variable temperature range :235±5℃;
2)Dip time:3±0.5s;
The area of dip tin should
capture the 95%
impregnated area
3.6.2
Resistance
to
soldering
heat
The switch will be inspect under such conditions below
Temperature and impregnated time
Trial measure
temperature(℃)
Time(s)
Slot welding method
260±5
5±1
Soldering method
350±5
3±0.5
All of the appearance,
motor functions,
electrical properties
are no abnormal.
3.7. Durability
NO.
Item
Test Condition
Criteria
3.7.1
Endurance
(According
to
UL61058)
1A 125VAC
Switch shall be operated according to following sequence
(Test1~Test2)
Voltage
Current
Power
Factor
Operation
Rate
Operation
Cycles
Test 1
125V
4.5A
0.75-0.8
6-10
Cycles/min
50cycles
Test2
125V
3A
0.75-0.8
6-10
Cycles/min
10000
cycles
Voltage proof:Test voltage shall be applied for
1 min(50~60Hz, Cut-off current:0.5mA)
3GPA125/250VAC
Operation Cycles:10,000 次 ;
Operation Frequency:15~20 次/min
Voltage proof:Test voltage shall be applied for
1 min(50~60Hz, Cut-off current:0.5mA)
Insulation
resistance
(item 4.2):
50MΩ MIN;
Voltage proof:
Terminal and
terminal:1000VAC
No dielectric
breakdown shall
occur.
Operating
characteristic
(item 5.1):
Within 20% of
specified
value .6000 cycles
temperature
rise: 30℃ MAX;
10000cycles
temperature
rise: 55℃ MAX;
No abnormalities
shall
be recognized in
appearance and
construction.
3.7.2
Endurance
(According to
EN61058-1
/IEC61058-1)
3(0.5)A250VAC
Operating Cycles:10,000 cycles
Operation Frequency:15~20 cycles/m 3(0.5)A 250VAC
Voltage proof:Test voltage shall be applied for
1 min(50~60Hz, Cut-off current:0.5mA)
Insulation
resistance(item 4.2):
50MΩ MIN
Voltage proof:
Terminal and
terminal:750VAC
Terminal and
ground:1500VAC
No dielectric
breakdown shall
occur.
Operating
characteristic
(item 5.1):
Within ±20% of
specified
value .Temperature
rise:55℃ MAX
No abnormalities
shall be recognized
in appearance
and construction
4. DRAWING & DIMENSION
5. CIRCUIT DIAGRAM
6.PACKING
6.1
Packing material:
Plastic box /
Double-layers paper carton6.2
Packing number:
100 pieces per box
4 inner cartons per shipping carton
Each shipping carton 10000 pieces6.3
Weight:
Gross Weight: 8.5kg
Net Weight: 7.0kg
6.4
Size:
31.0 x 25.0 x 34.5 CM / 0.045CBM
Approved Rating
Mark
Reference No.
3(0.5)A125/250VAC3GPA125/250VAC3RA125/250VAC40T85,1E4,50-60HzIP403 A, 30 V dc40T85,1E4, IP40
UL&CUL
E176213
VDE
3(0.5)A250VAC
CQC
CQC07002020246
NEMKO
SEMKO
FIMKO
3(0.5) A, 125/250 VAC3 RA, 125/250 VAC3 A,
30 V d.c.40T85, 1E4, 50-60Hz, IP40
DEMKO
D-00719
3(0.5)A250VAC
CE
AN501823730001
3(0.5)A250VAC
TUV
R50060067
3(0.5) A, 125/250 VAC3 RA, 125/250 VAC3 A,
30 V d.c.40T85, 1E4, 50-60Hz, IP40
ENEC
ENEC-00182
3(0.5)A250VAC 10E3 T85
EK
SU02030-8001A
3(0.5) A, 125/250 VAC3 RA, 125/250 VAC3 A,
30 V d.c.40T85, 1E4, 50-60Hz, IP40
CB
DK-5190
PARTS LIST
NO.
QUANTITY
Item
Material
1
1
plunger
Engineering plastic Black PPS-hGR40/41(UL94V-0)
2
1
cover
Engineering plastic Black PBT(UL94V—0)
3
1
Moving piece
Beryllium bronze C1720 HM QSn6.5-0.1
4
1
support
The brass strip H65 Plate with silver
5
1
case
Engineering plastic Black PBT(UL94V—0)
6
1
NC terminal
The brass strip H65 Plate with silver
7
1
contact
AgNi10, Gold plated
8
1
NO terminal
AgNi10/Cu