KAN-D3-6 side edge terminal ON-OFF SPST rocker switch for power tools
Series:KAN-D3-6
Type: KAN-D3-6
Construction category: D
Operation method: Rocker Action
Configuration: Single-Pole Single-Through (SPST)
Terminal form: #187 quick-connect Terminal
Mounting: Snap-In
Protection: IP40
- Applications
- Technical parameters
- Remarks
-
Home / Household Appliances
Electric kettle, Robot cleaner, Dust catcher, Vacuum cleaner, Coffee maker, Running machine etc.
Electronic Equipment
Toys, Power tools, Car control panel etc.
Medical Equipment
Communication Equipment
Automation Equipment
Automotive Electronics
Instrumentation
1.DETAIL SPECIFICATIONS:
Type:KAN-D3-6
Construction category:D
Operation method:Rocker Action
Configuration:Single-Pole Single-Through (SPST)
Terminal form:#250 quick-connect Terminal
Mounting:Snap-In
Protection:IP40
1.1OPERATING CHARACTERISTICSCharacteristics
Units
Standards
Note
Actuating Force
N
3±1.5 Max
Original 3±1.5 .
Contact Force
N
0.4 Min
Original 0.4 Min
Electrical Clearance
mm
3 Min
Original 3 Min
Note:
Actuating Force:The force required to move the actuator from the free to the operation position
1.2 GENERAL CHARACTERISTICS
1.2.1Application This specification is applied to KAN Rocker Switch used for electronic equipment.
1.2.2 Operating temperature range -25℃ to +105℃
1.2.3Test conditions Unless otherwise specified. The atmospheric conditions for making measurements and tests are as follows
Ambient temperature:15~35℃
Relative humidity:45~85%
Air pressure:86~106kPa (860~1060 mbar)
Should any doubt arise in judgment. tests shall be conducted at the following conditions.
Ambient temperature:20±2℃
Relative humidity:60~70%
Air pressure:86~106kPa (860~1060 mbar)
1.3 Appearance construction and dimensions
1.3.1 Appearance Switch shall have good finishing, and no rust crack or plating failures.
1.3.2 Construction and dimensions Refer to individual product drawing.
1.4. Electrical specificationsNO.
Items
Test conditions
Criteria
1.4.1
Contact
resistance
Shall be measured at
12A 24VDC by voltage
drop method after some
operations without load.
Applied position: Between
terminal and terminal
30mΩ MAX
1.4.2
Insulation
resistance
Test voltage:500VDC,
measured after 1 min ±5s
Applied position: 1)Between
terminal and terminal
2)Between terminal and ground
100MΩ MIN
1.4.3
Voltage
proof
Following test voltages shall
be applied for 1 min.
(Cut-off current:0.5mA)
1)Between terminal and
terminal :2000VAC/min
(50~60Hz)
2)Between terminal and
ground: 2500VAC/min
(50~60Hz)
No dielectric
breakdown
shall occur
1.5. ENVIRONMENT RESISTANCE
NO.
Item
Test conditions
Criteria
1.5.1
Cold
After testing at -25±2℃
for 96 h, the switch shall
be allowed to stand under
normal room temperature
and humidity condition for
1h, and then measurement
shall be made within 1 h.
water drops shall be
removed.
Contact
resistance
(item 4.1):
100mΩ MAX
Insulation
resistance
(item 4.2):
50MΩ MIN
Voltage proof:
(item 4.3)
No dielectric
breakdown
shall occur.
Operating
characteristic
(item 5.1):
Operating
characteristic
variety Within
±10% of
specified value .
No abnormalities
shall be
recognized in
appearance and
construction.
1.5.2
Dry heat
After testing at 105±2℃ for
96 h, the switch shall be
allowed to stand under
normal room temperature
and humidity condition for
1h, and then measurement
shall be made within 1 h.
1.5.3
Damp heat
After testing at 40±2℃ and
90-95%RH for 96 h, the
switch shall be allowed to
stand under normal room
temperature and humidity
condition for 1h, and then
measurement shall be made
within 1 h. water drops shall
be removed.
1.5.4
Change of
temperature
After 20 cycles of following
conditions the switch shall
be allowed to stand under
normal room temperature
and humidity condition for
1h, and then measurement
shall be made within 1 h.
water drops shall be
removed.
1.5.5
Salt mist
Switch shall be checked
after following lest.
1) Temperature: 35±2℃
2) Salt solution: 5±1%
(solids by mass)
3) Duration: 24±1h
After test, salt deposit
shall be removed in
running water
No remarkable
corrosion shall
be recognized
in metal part
1.6. WELDING CHARACTERISTICS
1.6.1
Solder
ability
Switch test under such conditions and
inspect after.
1)Variable temperature range :235±5℃;
2)Dip time:3±0.5s;
The area of dip
tin should capture
the 95%
impregnated area
1.6.2
Resistance to
soldering heat
The switch will be inspect under such
conditions below
Temperature and impregnated time
Trial measure
temperature
(℃)
Time
(s)
Slot welding method
260±5
5±1
Soldering method
350±5
3±0.5
All of the appearance,
motor functions,
electrical properties
are no abnormal.
1.7. ENDURANCE
NO.
Item
Test condition
Criteria
1.7.1
Endurance
(According to
UL61058)
10(10)250VAC
Switch shall be operated according to
following sequence
(Test1~Test2)
Voltage
Current
Power
factor
Operation
rate
Number
of
operation
Test1
250V
12A
0.75-0.8
6-10
cycles/min
50cycles
Test2
250V
10A
0.75-0.8
6-10
cycles/min
6000
cycles
Voltage proof(Cut-off current:0.5mA)
1GPA 125/250VAC ;
Switch shall be operated 6,000 cycles at 15-20 cycles/min.
Test voltages shall be applied for 1 minInsulation
resistance
(item 4.2):
30MΩ MIN
Voltage proof:
Terminal and
ground:1000VAC
No dielectric
breakdown
shall occur.
Operating
characteristic
(item 5.1):
Operating
characteristic
variety
Within ±20%
of specified
value .
6000 cycles
temperature
rise:30℃ MAX;
10,000 cycles
temperature
rise:55℃ MAX;
No abnormalities
shall be recognized
in appearance and
construction
1.7.2
Endurance
(According to
EN61058-1
/IEC61058-1)
15(15) A 125VAC
Switch shall be operated 10,000 cycles at 15~20 cycles/min
Voltage proof(Cut-off current:0.5mA)
Test voltages shall be applied for 1 min.Insulation
resistance
(item 4.2):
50MΩ MIN
Voltage proof:
Terminal and
terminal:750VAC
Terminal and
ground:1500
VAC
No dielectric
breakdown
shall occur.
Operating
characteristic
(item 5.1):
Operating
characteristic
variety
Within ±20%
of specified
value .
Temperature
rise:55℃ MAX
No abnormalities
shall be
recognized in
appearance and
construction
2.DRAWING & DIMENSION:
3. CIRCUIT DIAGRAM:
4. PACKING:
4.1
Packing material:
Plastic bag /
Double-layers paper carton4.2
Packing number:
100 pieces per bag
10 bags per inner carton
2 inner cartons per shipping cartonEach shipping carton 2000 pieces
4.3
Weight:
Gross Weight: 13.5kg
Net Weight: 12.0kg
4.4
Size:
31 x26 x27 CM /0.022CBM
SAFETY APPROVAL & RATING:
Approved Rating
Mark
Reference No.
15A 125VAC T105/55
UL&CUL
E215677
VDE
10(8)A 250VAC 16A250VAC
CQC
CQC09002031458
NEMKO
SEMKO
FIMKO
DEMKO
CE
TUV
ENEC
EK
CB
PARTS LIST:
ITEM
NAME
MATERIAL
1
Housing
Nylon: Dupont
3
Actuator
Nylon: Dupont
4
Terminal
Brass H62 with silver plated
5
Lever
Copper T2 with silver plated and silver alloy contact
6
Spring
Steel
Returned plastic should not exceed 20%.