1M31SWT2B4M7QES 3 Ways 6 Pins Metal ON-OFF-ON Rocker Arms Toggle Switch

Series:1M31SWT2B4M7QES

Description:

DETAIL SPECIFICATIONS:

Type:         1M31SWT2B4M7QES

Construction category: D type

Operation method: Gear shifting

Configuration: Three-Pole Double-Through (3PDT)

Terminal form: Solder Terminal

Mounting: Whole embedding

Protection: Comply with  IP40

Contact Now

  • Applications
  • Technical parameters
  • Remarks

1.Digital Products: digital camera, digital video and so on;   

2.Remote Control: the remote control of automobile domestic security products;   

3.Communication Products: mobile phone, vehicle-mounted phone, telephone set, building equipment, PDA and so on;  
                                             
4.Homehole appliances: TV set, microwave oven, electric rice cooker, electric fans ,refrigerator,washer;air-conditioning and so on;   
                                                                              
5.Security Products: visual interphone, monitor and so on;   
                      
6.Toys: electric toys and so on;   

7.Computer Products: PC camera and so on;   

8.Exercises Machines: treadmills, massage armchair and so on;                                                                    

9.Medical Device: sphygmomanometer, thermometer, hospital call system and so on;
      
10.Others:  laser pen ,Pointer,Wireless mouse remote control pen,Laser projection pen,page turner,electronic pen;MousePen;overhead projector and so on;

11.Operating switches in all types of electronic equipment such as audio devices, office devices, communication devices, measuring instruments, TVs, video recorders,automotive sets, etc.

12.Household appliances, electric force, telecommunications, machine tool, vessel, textile, printing, Mining machine,  Music Instrument, etc.

3.1 OPERATING CHARACTERISTICS 

Characteristics

Units

Standards

Requirements

Actuating Force

N

500gram 1000gram 2000gram.

500±100grams

1000±200grams

2000±400grams

 

 

3.2 GENERAL 

3.2.1 Application This specification is applied to1MS3 T8-XH SERIES Switch used for electronic instrument panel.

3.2.2 Operating Temperature Range -30 ~+85

3.2.3 Test Conditions  Unless otherwise specified. The atmospheric conditions for making measurements and

tests are as follows:

 

Ambient temperature: 15~35℃

Relative humidity: 45~85%

                              Air pressure: 86~106kPa (860~1060 mbar)

Should any doubt arise in judgment. It shall be conducted at the following conditions.

 

Ambient temperature: 20±2℃

Relative humidity: 60~70%

Air pressure: 86~106kPa (860~1060 mbar)

 

 

3.3 Appearance construction and dimensions 

3.3.1 Appearance     Switch shall have good finishing, and no rust crack or plating failures.

3.3.2 Construction and dimensions Refer to individual product drawing. 

 

 

 

3.4. Contact Rating 

NO.

Plating

Rating

3.4.1

Q=Silver

Fixed TerminalSilver plated over copper

Alloy. Movable contactSilver plated over

copper alloy.

5Amps @120VAC

or28VDC.

 

2Amps @250VAC.

3.4.2

C=Gold over silver

Fixed TerminalCopper alloy with silver

Plated over gold plate. Movable contactCopper alloy with silver

Plated over gold plate.

3.4.3

S=Silver,  tin-lead

Fixed TerminalCopper alloy with silver plated , tin-lead.

Movable contactSilver plated over

Copper alloy.

3.4.4

K=Gold over silver

tin-lead

Fixed TerminalCopper alloy with silver plated over gold plate, tin-lead. Movable contactCopper alloy with silver

Plated over gold plate.

 

 

3.5. Gold Plating Standard 

No.

Item

Plating

Rating

3.5.1

R=Gold

Fixed TerminalCopper alloy with gold. Plate over nickel plate. Movable contactCopper alloy with gold. Plate over nickel plate.

0.4 VA Max.

@20VAC or DC

Max.

 

 

3.5.2

G=Gold, tin-lead

Fixed TerminalCopper alloy with gold plate over nickel plate,tin-lead.

Movable contactCopper alloy with gold plated over nickel plate.

plate over nickel plate.

 

 

4. Test Sequence: 

Item

Description

Test Conditions

Requirements

1

Visual Examination

By Visual Examination check without and out pressure &testing.

 

There shall be no defects that affect the

serviceability of

the product.

2

Contact Resistance

@2-4VDC 100mA. For both

silver and gold plated contacts.

 

30mΩ  Max

3

Insulation

Resistance

Measurements shall be made following application of1000 V/ DC 100mA potential across terminals and cover.

1000MΩ min/1000V

4

Dielectric

Withstanding

Voltage

1000 VAC(50Hz or 60Hz) shall be applied across terminal sand cover for 1 minute.

There shall be no break down or flashover.

5

Solder Heat

Resistance

WAVE SOLDERING1Soldering Temperature:260±5℃.2Duration of Solder Immersion: 5 ±1   and3Frequency of Soldering Process 2times max.(PCB is 1.6mm in thickness)  2~4.

1Shall be free from

pronounced backlash

falling-off or breakage terminals2As shown in item

 

6

Vibration

Shall be vibrated in accordance with Method 201A ofMIL-STD-202F1Frequency: 10-55-10Hz in1-min/cycle.

As shown in item 2~4

7

Shock

Shall be shocked in accordance with Method 213B condition A ofMIL-STD-202F1Acceleration; 5kg2Action time: 11±1m seconds.3Testing Direction: 6 sides.4Test Cycle: 3 times in each direction.

As shown in item 2~4

8

Actuation Force

MODEL-1305N MECHANICAL TEST500gram 1000gram2000gram.

At for test the force.Force:500±100grams;1000±200grams;

2000±400grams

9

Operating Life

Measurements shall be made following the test forth below:

15A,120VAC resistive loadsilver plated. 2A,250VAC resistive loadsilver plated.0.4A, 20VAC resistive loadgold plated.2 Rate of Operation:  6-8operationcycles per minute.3  Electronics Life Test: 6,000 cycles.

1 Dielectric

Strength1000V.2  Insulation

Resistance:

1000MΩ  min.

Mechanical Life Test: 40,000 cycles.

Contact Resistance: 10mΩ  Max.

10

Resistance Low Temperature

Following the test set forth below the sample shall be left in normal temperature and humidity conditions for 1 hour before the measurements are made:1Temperature:-40±3℃

2Time:96 hours.

As shown  in item

2~4.

 

11

Resistance High Temperature

Following the test set forth below the sample shall be left in normal temperature and humidity conditions for an hour before the measurements are made:1Temperature:85±2℃2Time:96 hours.

1Asshownin item3~4.

2.InsulationResistance:1000MΩ

12

Resistance Humidity

Following the test set forth below

the sample shall be left in normal

temperature and humidity conditions

for an hour before the measurements

are made:1Temperature:40±2℃2Relative Humidity:90~95%3Time:96 hours.

1ContactResistance:

10 mΩ Max.

2Insulation

Resistance:

1000MΩ  min.

13

The SaltTesting

Following the test set forth belowthe sample shall be left in normal  1Temperature:35±2℃  2The ratio of salt-water5%  3The spray amout of salt- water1~2 ml/h.Time:48 hours.

 

 

 

 

 

 

 

The testing standard based on bubble, crack, and magnifying glass with gauge.

 

 

5. Precautions in Handling 

Care should be exercised so that flux from the upper part of the printed circuit

board does not adhere to the switch.

 

 

6. DRAWING & DIMENSION:  

 

     

 

 

7.CIRCUIT DIAGRAM 

  

 

 

 













8. PARTS LIST: 

Note: Returned plastic should not exceed 20%.

NO.

quantity

Items

Material

1

1

CASE

Diallyl phthalate (DAP) (UL94V-0)

2

1

ACTUATOR

Brass, chrome plated

3

1

BUSHING

Brass nickel plated

4

1

HOUSING

Stainless Steel

5

1

TERMINAL/CONTACT

Silver or gold plated

RoHS& Lead Free

 

9. PACKING: 

9.1

Packing material:

 Plastic box /

Five -layers paper carton

9.2

Packing number:

25pcs/bag, 4bags in a box  , 10 box in a cargo,   1000pcs/cargo

9.3

Weight:

 Gross Weight:  6 kg

 Net Weight:   3.85 kg

9.4

Size:

x  x mm

return