RT-S06-SW116-L4LBB hight current 2pins on-off SPST rocker switch replace hongwell

Series:RT-S06

Description:

Type:                                   RT-S06-SW116-L4NBB
Construction category:   D
Operation method:          Rocker Action
Configuration:                  Single-Pole Single-Through (SPST)
Terminal form:                  #250 quick-connect Terminal
Mounting:                          Snap-In
Protection:                        IP40

Contact Now

  • Applications
  • Technical parameters
  • Remarks

Home / Household Appliances
Electric kettle, Robot cleaner, Dust catcher, Vacuum cleaner, Coffee maker, Running machine etc.
Electronic Equipment
Toys, Power tools, Car control panel etc.
Medical Equipment
Communication Equipment
Automation Equipment
Automotive Electronics
Instrumentation

1.DETAIL SPECIFICATIONS:
Type:RT-S06-SW116-L4NBB
Construction category:D
Operation method:Rocker Action
Configuration:Single-Pole Single-Through (SPST)
Terminal form:#250 quick-connect Terminal
Mounting:Snap-In
Protection:IP40
1.1OPERATING CHARACTERISTICS

Characteristics

Units

Standards

Note

Actuating Force

N

6±2 Max

Original 6±2

Contact Force

N

0.4 Min

Original 0.4 Min

Electrical Clearance

mm

3 Min

Original 3 Min

Note:
Actuating Force:The force required to move the actuator from the free to the operation position
1.2 GENERAL CHARACTERISTICS
1.2.1Application This specification is applied to RT-S06 Rocker Switch used for electronic equipment.
1.2.2Operating temperature range 0℃ to 85℃
1.2.3Test conditions Unless otherwise specified. The atmospheric conditions for making measurements and tests are as follows  
Ambient temperature:15~35℃
Relative humidity:45~85%
Air pressure:86~106kPa (860~1060 mbar)
Should any doubt arise in judgment. tests shall be conducted at the following conditions.  
Ambient temperature:20±2℃
Relative humidity:60~70%
Air pressure:86~106kPa (860~1060 mbar)
1.3 Appearance construction and dimensions
1.3.1Appearance Switch shall have good finishing, and no rust crack or plating failures.
1.3.2 Construction and dimensions Refer to individual product drawing.
1.4. Electrical specifications

NO.

Items

Test conditions

Criteria

1.4.1

Contact 

resistance

Shall be measured 

at 50VAC by voltage 

drop method after 

some operations 

without load.

Applied position: 

Between terminal 

and terminal  

30mΩ MAX

1.4.2

Insulation 

resistance

Test voltage:500VDC, 

measured after 1 min 

±5s

Applied position: 1)

Between terminal 

and terminal 

2)Between terminal 

and ground

100MΩ MIN

1.4.3

Voltage 

proof

Following test voltages 

shall be applied for 1 min.

(Cut-off  current:0.5mA)

1)Between terminal and 

terminal 2000VAC/min 

(50~60Hz)

2)Between terminal and 

ground: 2000VAC/min 

(50~60Hz)

No dielectric 

breakdown

shall occur

1.5. ENVIRONMENT RESISTANCE

NO.

Item

Test conditions

Criteria

1.5.1

Cold

After testing 

at -25±2℃ 

for 96 h, the 

switch shall 

be allowed to 

stand under 

normal room 

temperature 

and humidity 

condition for 

1h, and then 

measurement 

shall be made 

within 1 h. 

water drops 

shall be 

removed.

Contact 

resistance

(item 4.1): 

100mΩ MAX

Insulation 

resistance 

(item 4.2):

50MΩ MIN

Voltage 

proof: 

(item 4.3)

No dielectric 

breakdown 

shall occur.

Operating 

characteristic 

(item 5.1):

Operating 

characteristic 

variety Within 

±10% of 

specified value .

No abnormalities 

shall be 

recognized in 

appearance 

and construction.

1.5.2

Dry heat

After testing at 

105±2℃ for 96 h, 

the switch shall 

be allowed to 

stand under 

normal room 

temperature 

and humidity 

condition for 

1h, and then 

measurement 

shall be made 

within 1 h.

1.5.3

Damp heat

After testing at 

40±2℃ and 

90-95%RH for 

96 h, the switch 

shall be allowed 

to stand under 

normal room 

temperature and 

humidity condition 

for 1h, and 

then measurement 

shall be 

made within 1 h. 

water drops 

shall be removed.

1.5.4

Change of

temperature

After 20 cycles of

 following 

conditions the 

switch shall 

be allowed to 

stand under 

normal room 

temperature 

and humidity 

condition for 1h,

and then 

measurement shall 

be made within 1 h. 

water 

drops shall be 

removed.

1.5.5

Salt mist

Switch shall be 

checked 

after following lest.

1) Temperature: 

35±2℃

2) Salt solution: 

5±1% 

(solids by mass)

3) Duration: 

24±1h

After test, salt 

deposit shall 

be removed in 

running water 

No remarkable 

corrosion 

shall be 

recognized in 

metal part

1.6. WELDING CHARACTERISTICS

 

1.6.1

 

Solder ability

Switch test under such conditions 

and inspect after. 

1Variable temperature range :235±5℃

2Dip time:3±0.5s

 

The area of dip 

tin should 

capture the 95% 

impregnated area

 

1.6.2

 

Resistance to 

soldering heat

 

The switch will be inspect under such 

conditions below

Temperature and impregnated time

Trial measure

temperature

Time

s

Slot welding method

260±5

5±1

Soldering method

350±5

3±0.5

 

 

All of the appearance, 

motor functions, 

electrical properties 

are no abnormal.  

1.7.  ENDURANCE

NO.

Item

Test condition

Criteria

1.7.1

Endurance

(According to

 UL61058)

16A  125VAC

Switch shall be operated according to 

following sequence

(Test1~Test2)

 

Voltage

Current

Power 

factor

Operation 

rate

Number 

of operation

Test1

125V

18A

0.75-0.8

6-10

cycles/min

50cycles

Test2

125V

16A

0.75-0.8

6-10

cycles/min

6000

cycles

Voltage proof(Cut-off current:0.5mA)

1GPA 125/250VAC ;

Switch shall be operated 6,000 cycles at 

15-20 cycles/min.

Test voltages shall be applied for 1 min

Insulation 

resistance

(item 4.2): 

30MΩ MIN

Voltage proof:

Terminal and 

ground:1000

VAC

No dielectric 

breakdown 

shall occur.

Operating 

characteristic 

(item 5.1):

Operating 

characteristic 

variety 

Within ±20% 

of specified 

value .

6000 cycles 

temperature 

rise:30℃ MAX;

10,000 cycles 

temperature 

rise:55℃ MAX;

 

No abnormalities 

shall be recognized 

in appearance and 

construction

1.7.2

Endurance

(According to 

EN61058-1

/IEC61058-1)

16(4)A  250VAC

Switch shall be operated 10.000 cycles at 

15~20 cycles/min

Voltage proof(Cut-off current:0.5mA)

Test voltages shall be applied for 1 min.

Insulation resistance

(item 4.2): 

50MΩ MIN

Voltage proof:

Terminal and 

terminal:750VAC

Terminal and 

ground:1500VAC

No dielectric 

breakdown 

shall occur.

Operating 

characteristic 

(item 5.1):

Operating 

characteristic 

variety 

Within ±20% 

of specified 

value .

Temperature 

rise:55℃ MAX

No abnormalities 

shall be recognized 

in appearance and 

construction

2. DRAWING & DIMENSION:

3.CIRCUIT DIAGRAM:

4. PACKING:

4.1

Packing material:

Plastic bag / 
Double-layers paper carton

4.2

Packing number:

200 pieces per bag 
8 bags per shipping carton
Each shipping carton 1600 pieces

4.3

Weight:

Gross Weight:  8 kg

Net Weight:   7 kg

4.4

Size:

40*30*23CM /0.0276㎡

SAFETY APPROVAL & RATING:

Approved Rating

Mark

Reference No.

16A 125VAC 60HZ

UL&CUL

E300970

 

VDE

 

 

CQC

 

 

NEMKO

 

 

SEMKO

 

 

FIMKO

 

 

DEMKO

 

 

CE

 

 

TUV

 

 

ENEC

 

 

EK

 

 

CB

 

PARTS LIST:

ITEM

NAME

MATERIAL

1

BASE

PLASTIC

2

BUTTON

PLASTIC

 

COVER

PLASTIC

3

TERMINAL

 TINNED BRASS

4

CONTACT

AgNi10

5

SPRING

SWC

7

LINGHT

220KΩ 1/4W

Returned plastic should not exceed 20%.

return