MR-6A-SW210-C5N-BB ON-OFF 20mm oval 4pins DPST rocker switch for medical machine

Series:MR6

Description:

Type:                                  MR-6A-SW210-C5N-BB
Construction category:  D
Operation method:         Rocker Action
Configuration:                 Double-Pole Single Through (DPST)
Terminal form:                #187quick-connect Terminal
Mounting:                         Snap-In
Protection:                       IP40

Contact Now

  • Applications
  • Technical parameters
  • Remarks

Home / Household Appliances
Electric kettle, Robot cleaner, Dust catcher, Vacuum cleaner, Coffee maker, Running machine etc.
Electronic Equipment
Toys, Power tools, Car control panel etc.
Medical Equipment
Communication Equipment
Automation Equipment
Automotive Electronics
Instrumentation

1. DETAIL SPECIFICATIONS:
Type:                                MR-6A-SW210-C5N-BB
Construction category:  D
Operation method:        Rocker Action
Configuration:               Double-Pole Single Through (DPST)
Terminal form:               #187quick-connect Terminal
Mounting:                      Snap-In
Protection:                     IP40
1.1    OPERATING CHARACTERISTICS

Characteristics

Units

Standards

Note

Actuating Force

N

4±2 Max

Original4±2.  .

Contact Force

N

0.4 Min

Original 0.4 Min

Electrical Clearance

mm

3 Min

Original 3 Min

Note:
Actuating Force:The force required to move the actuator from the free to the operation position

1.2 GENERAL CHARACTERISTICS
1.2.1 Application                This specification is applied to MR-6A Rocker Switch used for electronic equipment.
1.2.2 Operating temperature range            0℃ ~ 85℃
1.2.3Test conditions                  Unless otherwise specified. The atmospheric conditions for making measurements and tests are as follows  
Ambient temperature:            15~35℃
Relative humidity:            45~85%
Air pressure:                86~106kPa (860~1060 mbar)
Should any doubt arise in judgment. tests shall be conducted at the following conditions.  
     Ambient temperature:            20±2℃
Relative humidity:            60~70%
Air pressure:                86~106kPa (860~1060 mbar)
1.3 Appearance construction and dimensions
1.3.1 Appearance                     Switch shall have good finishing, and no rust crack or plating failures.
1.3.2 Construction and dimensions    Refer to individual product drawing.
1.4. Electrical specifications

 

NO.

Items

Test conditions

Criteria

1.4.1

Contact resistance

Shall be measured at
12A 24VDC by voltage
drop method after some
operations without load.

Applied position: Between
terminal and terminal  

50mΩ MAX

1.4.2

Insulation resistance

Test voltage:500VDC,
measured after 1 min ±5s

Applied position: 1)
Between terminal and terminal 

2)Between terminal and ground

100MΩ MIN

1.4.3

Voltage proof

Following test voltages
shall be applied for 1 min.

(Cut-off  current:0.5mA)

1)Between terminal and terminal :
1500VAC (50~60Hz)

No dielectric breakdown

shall occur

1.5. ENVIRONMENT RESISTANCE

 

NO.

Item

Test conditions

Criteria

1.5.1

Cold

After testing at -25±2℃ for 96 h,
the switch shall be allowed to stand
under normal room temperature and
humidity condition for 1h, and then
measurement shall be made within 1 h.
water drops shall be removed.

Contact resistance(item 4.1): 

100mΩ MAX

Insulation resistance (item 4.2):

50MΩ MIN

Voltage proof: (item 4.3)

No dielectric breakdown shall occur.

Operating characteristic (item 5.1):

Operating characteristic variety
Within ±10% of specified value .

No abnormalities shall be recognized i
n appearance and construction.

1.5.2

Dry heat

After testing at 105±2℃ for 96 h,
the switch shall be allowed to stand
under normal room temperature and
humidity condition for 1h, and then
measurement shall be made within 1 h.

1.5.3

Damp heat

After testing at 40±2℃ and 90-95%RH
for 96 h, the switch shall be allowed to
stand under normal room temperature
and humidity condition for 1h, and then
measurement shall be made within 1 h.
water drops shall be removed.

1.5.4

Change of

temperature

After 20 cycles of following conditions
the switch shall be allowed to stand under
normal room temperature and humidity
condition for 1h, and then measurement
shall be made within 1 h. water drops
shall be removed.

1.5.5

Salt mist

Switch shall be checked after following lest.

1) Temperature: 35±2℃

2) Salt solution: 5±1% (solids by mass)

3) Duration: 24±1h

After test, salt deposit shall be
removed in running water 

No remarkable corrosion
shall be recognized in metal part

1.6. WELDING CHARACTERISTICS

 

 

1.6.1

 

Solder ability

Switch test under such conditions and inspect after. 

1)Variable temperature range :235±5℃;

2)Dip time:3±0.5s;

 

The area of dip tin
should capture the
95% impregnated area

 

1.6.2

 

Resistance to
soldering heat

 

The switch will be inspect under such conditions below

Temperature and impregnated time

Trial measure

temperature(℃)

Time(s)

Slot welding method

260±5

5±1

Soldering method

350±5

3±0.5

 

 

All of the appearance,
motor functions, 

electrical
properties are no 

abnormal.  

1.7. ENDURANCE

 

NO.

Item

Test condition

Criteria

1.7.1

Endurance

(According to

 UL61058)

12A 125VAC

Switch shall be operated according to following sequence

(Test1~Test2)

 

Voltage

Current

Power factor

Operation
rate

Number of
operation

Test1

125V

13A

0.75-0.8

6-10

cycles/min

50cycles

Test2

125V

12A

0.75-0.8

6-10

cycles/min

6000cycles

Voltage proof(Cut-off current:0.5mA)

1GPA 125/250VAC ;

Switch shall be operated 6,000 cycles at 15-20 cycles/min.

Test voltages shall be applied for 1 min

Insulation 

resistance

(item 4.2): 

30MΩ MIN

Voltage 

proof:

Terminal 

and ground:

1000VAC

No dielectric 

breakdown 

shall occur.

Operating 

characteristic 

(item 5.1):

Operating 

characteristic 

variety 

Within ±20% 

of specified 

value .

6000 cycles 

temperature 

rise:30℃ MAX;

10,000 cycles 

temperature 

rise:55℃ MAX;

 

No abnormalities 

shall be
recognized in 

appearance
and construction

1.7.2

Endurance

(According to
EN61058-1

/IEC61058-1)

10A 250VAC

Switch shall be operated 10,000 cycles at 15~20 cycles/min

Voltage proof(Cut-off current:0.5mA)

Test voltages shall be applied for 1 min.

Insulation 

resistance

(item 4.2): 

50MΩ MIN

Voltage 

proof:

Terminal and 

terminal:

750VAC

Terminal and 

ground:1500

VAC

No dielectric 

breakdown 

shall occur.

Operating 

characteristic 

(item 5.1):

Operating 

characteristic 

variety 

Within ±20% 

of specified 

value .

Temperature 

rise:55℃ MAX

No 

abnormalities 

shall be 

recognized
in appearance 

and construction

2. DRAWING & DIMENSION:


3. CIRCUIT DIAGRAM:


4. PACKING:

4.1

Packing material:

Plastic bag / 
Double-layers paper carton

4.2

Packing number:

100 pieces per bag 
10 bags per inner carton
3 inner cartons per shipping carton 

1ipping carton 3000 pieces

4.3

Weight:

Gross Weight:  24 kg

Net Weight:  22.5 kg

4.4

Size:

57*27*32CM /0.049248CBM




SAFETY APPROVAL & RATING:

Approved Rating

Mark

Reference No.

12A 125V 60GP T85

UL&CUL

E466013

 

VDE

 

10A 250VAC T85 1E4 PTI175 

CQC

CQC13003091203

 

NEMKO

 

 

SEMKO

 

 

FIMKO

 

 

DEMKO

 

 

CE

 

 

TUV

 

 

ENEC

 

 

EK

 

 

CB

 


PARTS LIST:

ITEM

NAME

MATERIAL

1

BODY

NYLON66

2

ACTUATOR

NYLON66

3

TEMINAL

BRASS,AILVER OR TIN PLATED

return